CUSTOM SOLUTIONS / FAILURE ANALYSIS

O-Ring Failure Analysis Starts with the Evidence Available.

A visible failure sign is a useful starting point, not a complete diagnosis. We review the available part, service conditions, gland information, and material evidence to identify the next questions.

Request a Technical Review

We aim to provide an initial response within 12 hours.

01 / REVIEW METHOD

A seal failure is a system question.

The same visible change can have more than one contributing mechanism. Material, gland condition, sealed media, temperature, pressure, motion, installation, and service history can all matter. A useful review compares the failed part with the actual sealing condition rather than treating one symptom as a final answer.

  1. 01Observe
  2. 02Compare
  3. 03Clarify conditions
  4. 04Define next checks

02 / FAILURE SIGNALS

Four failure signals to review

These sections describe visible clues and the information that helps clarify them. A clue can involve more than one mechanism. These sections do not replace application-specific material or design review.

01 / FAILURE SIGNAL

Compression Set

Installed O-ring under compression compared with incomplete recovery after removal, against an original uncompressed outline.
As installed: under compression. After removal: incomplete recovery. Dashed outline: original uncompressed cross-section.Illustrative only — not to scale.

Typical Appearance

After removal and a period of recovery, a seal may retain flattened contact areas or reduced cross-section height compared with an unused reference. Normal installed compression is not itself compression set.

Possible Causes

Compound and cure system, sustained squeeze, temperature, exposure time and media-related changes can affect recovery.

What to Check

Compare the recovered part with an unused seal and review gland dimensions, squeeze and service history. ASTM D395 measures residual deformation under specified compression and recovery conditions; appearance alone does not quantify compression set.

Retained flats are a clue, not proof of a single cause or inevitable leakage.

02 / FAILURE SIGNAL

Abrasion

Moving shaft contacts the bottom of the installed cross-section; the removed section shows local material loss at the corresponding bottom contact surface.
Wear marks may appear along the direction of motion.Illustrative only — not to scale.

Typical Appearance

A dynamic contact surface may show local material loss, wear or fine marks along the motion path. The illustrated worn face corresponds to the shaft contact below, rather than deformation on both compression faces.

Possible Causes

Mating-surface roughness, inadequate lubrication, particles, misalignment or operating cycles can contribute to wear.

What to Check

Confirm the moving surface and wear location. Check surface finish, lubrication, contamination, gland alignment and assembly history. Distinguish removed material from retained deformation; more than one mechanism may be present.

A flattened face alone does not establish abrasion.

03 / FAILURE SIGNAL

Chemical Exposure

Original unexposed cross-section and separate possible swelling and shrinkage outcomes, using the same original reference outline.
Original — Unexposed Reference / Possible Swelling / Possible Shrinkage. Dashed outlines represent the same original cross-section.Illustrative only — not to scale.

Typical Appearance

Media exposure may produce swelling, shrinkage or changes in surface condition and elasticity. The three states show separate possible outcomes, not a required sequence; the drawn sizes are not measured volume changes.

Possible Causes

Fluid absorption, extraction of soluble ingredients or chemical degradation may contribute. The exact compound, media, concentration, temperature and exposure duration matter.

What to Check

Compare with an unexposed reference and identify the exact media, additives and cleaning agents. ASTM D471 evaluates changes in rubber properties after controlled liquid exposure; it does not cover every gas exposure or establish field compatibility by itself.

A material family name or compatibility-table rating is not a field-use guarantee.

04 / FAILURE SIGNAL

Thermal Degradation

Possible local surface cracking surrounded by review factors: operating temperature, exposure duration, thermal cycling and operating media.
Possible Surface Cracking. Review Operating Temperature, Exposure Duration, Thermal Cycling and Operating Media.Illustrative only — not to scale.

Typical Appearance

Prolonged heat exposure may change hardness or elastic recovery, and may be accompanied by surface cracking, pitting or retained deformation. Not all heat-related damage appears as cracking.

Possible Causes

Operating temperature and duration, thermal cycling, frictional heating, operating media and compound stability can interact.

What to Check

Review continuous and peak temperatures, time, cycling and media alongside gland and motion conditions. ASTM D573 assesses changes in rubber properties after air-oven aging; it does not reproduce every service environment or prove heat was the root cause.

Cracks alone do not identify excessive temperature; chemical and other mechanisms may overlap.

OTHER REVIEW PATHS

Other Failure Patterns to Consider

Extrusion & Nibbling

Pressure can force elastomer into a clearance gap. Repeated loading and movement can leave torn or nibbled edges. Check pressure peaks, actual clearance, component deflection, compound hardness and any required backup support.

Installation Damage

Sharp edges, exposed threads or assembly tools can scratch or cut a seal during installation. Check lead-in chamfers, thread protection, lubrication, seal position and the assembly path before attributing damage to service conditions.

An O-ring can leak even without visible damage.

Gland dimensions, tolerances, squeeze and installation position can affect sealing even when the part looks intact. Review the complete sealing arrangement as well as the seal.

The ASTM methods mentioned above explain controlled material tests, not reports of FLUID testing. Laboratory results do not establish service life or guarantee sealing in a particular application.

07 / TECHNICAL REVIEW INPUTS

Start with what is available.

The following information can help clarify the next check. It is not required to begin a conversation.

  • Failed part or available photos
  • Exact sealed media and known additives
  • Operating temperature, pressure, and service duration
  • Static or dynamic motion, including cycle information where available
  • Available dimensions, gland details, or comparison with an unused part
  • Installation and assembly information
  • Available material data or prior service history

08 / TECHNICAL REVIEW

From visible signs to the next technical question

  1. 01

    Tell us the sealing issue and the information available.

  2. 02

    We can identify the next information needed for a technical review.

  3. 03

    The next discussion may involve the part, service conditions, material evidence, or gland details.

RELATED TECHNICAL PATHS

Need to review a material choice against the application? Explore Material Selection →

Need to discuss seal geometry, gland details or a revised arrangement? Explore Seal Design →

START A TECHNICAL REVIEW

Need to review a failed seal?

Start with the information available. We can identify the next details needed for a technical review.

WhatsApp